Fresh Hot Water System,
Series:
Fresh Hot Water System
Frischwassersystem Heliotherm
+
Your advantages
  • Long operating life and higher safety (high quality components)
  • Bacteria-resistant and protected against legionella (instant water heater)
  • Always fresh water- no storage
  • Lowest operating costs due to optimum hydraulics and low buffer temperature
  • Energy-saving and low-maintenance operation
  • No electric heating required (no heating element, no hidden costs)
  • Prompt ready hot water for the entire family
  • Connection possibilities for various heat generators, heating systems, thermometers, sensors, solar etc.
The Heliotherm Plus
  • Quality "Made in Austria", development and production in Tyrol
ZH-FS5101 - Special fresh hot water system, Type 500
ZH-FS9101 - Special fresh hot water system, Type 900
ZH-FS15101 - Special fresh hot water system, Type 1500
ZH-S3101S - Buffer storage, Type 300
ZH-S5101S - Buffer storage, Type 500
ZH-S9101S - Buffer storage, Type 850
ZH-KS900 - Combined buffer storage, Type 900
ZH-KS500 - Combined buffer storage, Type 500
Technical Data
Total content
472 L
Fresh hot water content
-
Heating content
-
Service water content
-
Heating buffer content
-
Empty weight
111 kg
Dimensions without insulation (Ø x H)
600 x 1930 mm
Dimensions with insulation (Ø x H)
760 x 1.930 mm
Tilted dimension
2.080 mm
Max. permitted FW operating pressure
-
Max. permitted heating pressure
3 bar
Max. permitted temperature
95 °C
Energy efficiency class
B
Single flow capacity (DHW up to 38 °C) with charged buffer at 55 °C - only in connection with Heliotherm FHWS
401 L
Technical Data
Total content
805 L
Fresh hot water content
-
Heating content
-
Service water content
-
Heating buffer content
-
Empty weight
165 kg
Dimensions without insulation (Ø x H)
790 x 1.990 mm
Dimensions with insulation (Ø x H)
990 x 1.990 mm
Tilted dimension
2.015 mm
Max. permitted FW operating pressure
-
Max. permitted heating pressure
3 bar
Max. permitted temperature
95 °C
Energy efficiency class
B
Single flow capacity (DHW up to 38 °C) with charged buffer at 55 °C - only in connection with Heliotherm FHWS
558 L
Technical Data
Total content
1.500 L
Fresh hot water content
-
Heating content
-
Service water content
-
Heating buffer content
-
Empty weight
246 kg
Dimensions without insulation (Ø x H)
1.100 x 1.920 mm
Dimensions with insulation (Ø x H)
1.340 x 1.920 mm
Tilted dimension
2.335 mm
Max. permitted FW operating pressure
-
Max. permitted heating pressure
3 bar
Max. permitted temperature
95 °C
Energy efficiency class
-
Single flow capacity (DHW up to 38 °C) with charged buffer at 55 °C - only in connection with Heliotherm FHWS
1.232 L
Technical Data
Total content
300 L
Fresh hot water content
-
Heating content
-
Service water content
-
Heating buffer content
-
Empty weight
80 kg
Dimensions without insulation (Ø x H)
500 x 1.900 mm
Dimensions with insulation (Ø x H)
660 x 1.900 mm
Tilted dimension
2.011 mm
Max. permitted FW operating pressure
-
Max. permitted heating pressure
3 bar
Max. permitted temperature
95 °C
Energy efficiency class
B
Single flow capacity (DHW up to 38 °C) with charged buffer at 55 °C - only in connection with Heliotherm FHWS
-
Technical Data
Total content
472 L
Fresh hot water content
-
Heating content
-
Service water content
-
Heating buffer content
-
Empty weight
111 kg
Dimensions without insulation (Ø x H)
-
Dimensions with insulation (Ø x H)
760 x 1.930 mm
Tilted dimension
2.080 mm
Max. permitted FW operating pressure
-
Max. permitted heating pressure
3 bar
Max. permitted temperature
95 °C
Energy efficiency class
B
Single flow capacity (DHW up to 38 °C) with charged buffer at 55 °C - only in connection with Heliotherm FHWS
-
Technical Data
Total content
805 L
Fresh hot water content
-
Heating content
-
Service water content
-
Heating buffer content
-
Empty weight
165 kg
Dimensions without insulation (Ø x H)
790 x 1.990 mm
Dimensions with insulation (Ø x H)
990 x 1.990 mm
Tilted dimension
2.015 mm
Max. permitted FW operating pressure
-
Max. permitted heating pressure
3 bar
Max. permitted temperature
95 °C
Energy efficiency class
B
Single flow capacity (DHW up to 38 °C) with charged buffer at 55 °C - only in connection with Heliotherm FHWS
-
Technical Data
Total content
805 L
Fresh hot water content
-
Heating content
-
Service water content
563 L
Heating buffer content
242 L
Empty weight
183 kg
Dimensions without insulation (Ø x H)
790 x 1.865 mm
Dimensions with insulation (Ø x H)
990 x 1.865 mm
Tilted dimension
1.905 mm
Max. permitted FW operating pressure
3 bar
Max. permitted heating pressure
3 bar
Max. permitted temperature
95 °C
Energy efficiency class
-
Single flow capacity (DHW up to 38 °C) with charged buffer at 55 °C - only in connection with Heliotherm FHWS
558 L
Technical Data
Total content
472 L
Fresh hot water content
-
Heating content
-
Service water content
377 L
Heating buffer content
95 L
Empty weight
117 kg
Dimensions without insulation (Ø x H)
600 x 1.930 mm
Dimensions with insulation (Ø x H)
760 x 1.930 mm
Tilted dimension
2.080 mm
Max. permitted FW operating pressure
3 bar
Max. permitted heating pressure
3 bar
Max. permitted temperature
95 °C
Energy efficiency class
B
Single flow capacity (DHW up to 38 °C) with charged buffer at 55 °C - only in connection with Heliotherm FHWS
351 L
Fresh Hot Water System,
Series:
Fresh Hot Water System

Quality criteria

EHPA Seal of Approval
SG Ready
Quality Label ISO Certification
Energy Label
Subsidies

Quality assurance for heat pumps: The heat pump quality seal was introduced by the EHPA in 2009 to create uniform measurable standards in Europe, according to which the quality of the product and service can be assessed. The award in Austria is carried out by the national quality seal commission of Austria under the chairmanship of Prof. Hermann Halozan / Graz University of Technology. Other members of the national commission are made up of experts from the Vorarlberg Energy Institute, the Tyrolean Hydropower Plant as well as representatives of the board Wärmepumpe Austria Association and a representative of the Austrian testing institute (AIT: Austrian Institute of Technology).

The SG Ready label is awarded to heat pump products that make it possible to integrate the individual heat pump control technology into an intelligent power grid.

Quality management systems are the leading modern management tools per se. Based on the DIN EN ISO 9001 standard applied worldwide which enable companies to systematically design their conduct in such a way that the customer requirements are met. Meaning, the customer receives his product or the service exactly as he ordered it. A satisfied customer remains faithful to the supplier. The independent and external certification center ALL-CERT found that Heliotherm fulfills and complies with customer requirements.

The EU Energy Label, already known to other electrical appliances (refrigerator, lighting, etc.), has been mandatory since September 26, 2015 for space heating appliances and therefore also for heat pumps. The efficiency of heating and / or hot water systems is now better comparable. As a consumer, you benefit from a faster decision-making process with regard to an efficient product. The advantage of the heat pumps is clear, as a rule they reach the highest efficiency classes of A ++ & A +++. Class A is only physically attainable for gas or oil boilers.

The high annual performance factors (SPF) are reached by Heliotherm heat pumps, obtaining maximum subsidies and grants from the federal, municipal or utility companies. Subsidy awards vary from country and region to region.

Technical Specifications Heliotherm Heat Pumps

dsi Technology®: electronic working fluid regulation

By contrast, a conventional mechanical working fluid control, to a heat pump with the electronically controlled working fluid regulating device, patented dsi Technology® in the refrigeration cycle. This mechanism masters the difference in this cutting edge technology for higher efficiency. Additionally, more parameters can be taken into account and the expansion valve can respond faster to changes, adapting to the required operating conditions.

twin-x cooling optimization

Thanks to the patented twin-x cooling technology® exclusively by Heliotherm, unused energy can be extracted from the refrigeration circuit through a second special heat exchanger. The gained energy is delivered directly to the heating water. This process engineered by Heliotherm, contributes to an even better use of environmental energy.

Stepless modulation

Since 1994 Heliotherm is a pioneer in construction and development of heat pumps. Modulation is part of this company's Stepping Stones of research and development of modulation and is therefore the technology leader in this application. Heliotherm's stepless modulation technology has been proven for many years by its reliability and efficiency. The Heliotherm modulation technology opens up entirely new possibilities for the application of highly efficient heat pumps. As needed by the heating demand, the modulating heat pump can achieve the desired performance. In addition, the heat pump is protected by a soft start up conduct and its lifespan is prolonged.

Stepless modulation Heliotherm video