Comfort Compact Air Heat Pump,
Series:
Sensor
Comfort Compact Luft Wärmepumpe, Baureihe Sensor
+
+
+
+
+
+
Your advantages
  • Award-winning design by Red Dot Award 2016, customized interface
  • Highest energy efficiency rate of all air heat pumps on the market
  • Silent (confirmed sound tests by the AIT on April 11, 2016)
  • Can be installed in any building & approval-free
  • Defrosting process with highest efficient even at the lowest outdoor temperatures
The ideal complement
  • Active cooling
  • PV combination possible
  • Combine various heating systems possible
  • Fresh hot water system for domestic water heating
  • Hot water buffer storage for domestic water heating
  • 230 V single phase
The Heliotherm Plus
  • Best in Class: World's most efficient heat pump technology > Maximum subsidies from state and federal sources
  • Quality "Made in Austria", development and production in Tyrol
  • 2 year manufacturer's warranty 
  • Significant lower operating costs due to smart patented and registered refrigerant cycle operations (twin-x technology, dsi-technology)
  • Worldwide heat pump remote control access via internet
S08L-M-CC
S12L-M-CC
S18L-M-CC
Performance data EN 14511 (ΔT5K)
Modulating range A-7W35
2,6 - 10,1 kW
Modulating range A2W35
3,1 - 11,1 kW
Heat output A2W35
6,3 kW
Performance COP A2W35
4,3
Modulating range A7W35
4,8 - 11,8 kW
Performance data EN 14825 / Energy Label
Performance SCOP A2W35 (medium - Strasbourg)
4,5
Seasonal conditional room heating- energy efficiency 35 °C / 55 °C ƞs
177 / 126
Category for room heating energy efficiency 35 °C / 55°C
A+++ / A++
Package energy efficiency class 35 °C ηs *)
-
Package energy efficiency class heating 35 °C
A+++
A-Rated acoustic capacity & level at A7/W55 acc. to EN12102
48 dB(A)
Performance data Option reversible cooling EN 14825
Cooling capacity A35W18
8,2 kW
EER at A35W18
4,0
SEER at A35W18
6,0
Evaporator / Energy source
Type
Lamellenverdampfer
Evaporator area
60
Fan type
Axialventilator mit Eulenflügel
Condenser / Heating side
Type
Plattenwärmetauscher
Material
Edelstahl / Cu gelötet
Nominal volume current heating circuit
2,4 m3/h
Residual pressure head heating cycle, ΔT = 5K
2,5 mWS
Water content - heating cycle (Heatpump)
2,5 L
Max. operating pressure
3 bar
Temperature heating cycle (max.)
62 °C
Electrical data
Nominal voltage compressor
3/N/PE/400 V/50 Hz
Nominal voltage regulating control
1/N/PE/230 V/50 Hz
Operating current max. (compressor and regulator)
13 A
Starting current
6A
Fuse type C (slow) 3-pole + N
20 A
Frq. inverter protection Type A
63 A / 30 mA
Technical Data
Refrigerant
R410a
Refrigerant fill amount
4,9 kg
Refrigerant filling quantity at option reversible
7,0 kg
Dimensions (H x W x D)
1.704 x 896 x 585 mm
Empty weight
215 kg
Heating connection: H. Outlet / H. Inlet
5/4"
Performance data EN 14511 (ΔT5K)
Modulating range A-7W35
4,1 - 12,2 kW
Modulating range A2W35
4,9 - 15,8 kW
Heat output A2W35
6,3 kW
Performance COP A2W35
4,0
Modulating range A7W35
6,8 - 16,5 kW
Performance data EN 14825 / Energy Label
Performance SCOP A2W35 (medium - Strasbourg)
4,6
Seasonal conditional room heating- energy efficiency 35 °C / 55 °C ƞs
180 / 119
Category for room heating energy efficiency 35 °C / 55°C
A+++ / A++
Package energy efficiency class 35 °C ηs *)
-
Package energy efficiency class heating 35 °C
A+++
A-Rated acoustic capacity & level at A7/W55 acc. to EN12102
50 dB(A)
Performance data Option reversible cooling EN 14825
Cooling capacity A35W18
11,0 kW
EER at A35W18
4,2
SEER at A35W18
5,7
Evaporator / Energy source
Type
Lamellenverdampfer
Evaporator area
80
Fan type
Axialventilator mit Eulenflügel
Condenser / Heating side
Type
Plattenwärmetauscher
Material
Edelstahl / Cu gelötet
Nominal volume current heating circuit
2,6 m3/h
Residual pressure head heating cycle, ΔT = 5K
3,4 mWS
Water content - heating cycle (Heatpump)
2,8 L
Max. operating pressure
3 bar
Temperature heating cycle (max.)
62 °C
Electrical data
Nominal voltage compressor
3/N/PE/400 V/50 Hz
Nominal voltage regulating control
1/N/PE/230 V/50Hz
Operating current max. (compressor and regulator)
19 A
Starting current
8 A
Fuse type C (slow) 3-pole + N
20 A
Frq. inverter protection Type A
63 A / 30 mA
Technical Data
Refrigerant
R410a
Refrigerant fill amount
6,6 kg
Refrigerant filling quantity at option reversible
9,0 kg
Dimensions (H x W x D)
1.702 x 935 x 1.002 mm
Empty weight
256 kg
Heating connection: H. Outlet / H. Inlet
5/4"
Performance data EN 14511 (ΔT5K)
Modulating range A-7W35
5,1 - 13,7 kW
Modulating range A2W35
6,6 - 18,9 kW
Heat output A2W35
7,1 kW
Performance COP A2W35
4,1
Modulating range A7W35
8,6 - 21,4 kW
Performance data EN 14825 / Energy Label
Performance SCOP A2W35 (medium - Strasbourg)
5,0
Seasonal conditional room heating- energy efficiency 35 °C / 55 °C ƞs
195 / 133
Category for room heating energy efficiency 35 °C / 55°C
A+++ / A++
Package energy efficiency class 35 °C ηs *)
-
Package energy efficiency class heating 35 °C
A+++
A-Rated acoustic capacity & level at A7/W55 acc. to EN12102
51 dB(A)
Performance data Option reversible cooling EN 14825
Cooling capacity A35W18
13,8 kW
EER at A35W18
4,0
SEER at A35W18
6,1
Evaporator / Energy source
Type
Lamellenverdampfer
Evaporator area
100
Fan type
Axialventilator mit Eulenflügel
Condenser / Heating side
Type
Plattenwärmetauscher
Material
Edelstahl / Cu gelötet
Nominal volume current heating circuit
3,1 m3/h
Residual pressure head heating cycle, ΔT = 5K
4,0 mWS
Water content - heating cycle (Heatpump)
3,1 L
Max. operating pressure
3 bar
Temperature heating cycle (max.)
62 °C
Electrical data
Nominal voltage compressor
400 V
Nominal voltage regulating control
230 V
Operating current max. (compressor and regulator)
22 A
Starting current
9 A
Fuse type C (slow) 3-pole + N
25 A
Frq. inverter protection Type A
63 A / 30 mA
Technical Data
Refrigerant
R410a
Refrigerant fill amount
8,0 kg
Refrigerant filling quantity at option reversible
10,0 kg
Dimensions (H x W x D)
1.702 x 935 x 1.002 mm
Empty weight
262 kg
Heating connection: H. Outlet / H. Inlet
5/4"
Comfort Compact Air Heat Pump,
Series:
Sensor

Quality criteria

EHPA Seal of Approval
SG Ready
Quality Label ISO Certification
Energy Label
Subsidies

Quality assurance for heat pumps: The heat pump quality seal was introduced by the EHPA in 2009 to create uniform measurable standards in Europe, according to which the quality of the product and service can be assessed. The award in Austria is carried out by the national quality seal commission of Austria under the chairmanship of Prof. Hermann Halozan / Graz University of Technology. Other members of the national commission are made up of experts from the Vorarlberg Energy Institute, the Tyrolean Hydropower Plant as well as representatives of the board Wärmepumpe Austria Association and a representative of the Austrian testing institute (AIT: Austrian Institute of Technology).

The SG Ready label is awarded to heat pump products that make it possible to integrate the individual heat pump control technology into an intelligent power grid.

Quality management systems are the leading modern management tools per se. Based on the DIN EN ISO 9001 standard applied worldwide which enable companies to systematically design their conduct in such a way that the customer requirements are met. Meaning, the customer receives his product or the service exactly as he ordered it. A satisfied customer remains faithful to the supplier. The independent and external certification center ALL-CERT found that Heliotherm fulfills and complies with customer requirements.

The EU Energy Label, already known to other electrical appliances (refrigerator, lighting, etc.), has been mandatory since September 26, 2015 for space heating appliances and therefore also for heat pumps. The efficiency of heating and / or hot water systems is now better comparable. As a consumer, you benefit from a faster decision-making process with regard to an efficient product. The advantage of the heat pumps is clear, as a rule they reach the highest efficiency classes of A ++ & A +++. Class A is only physically attainable for gas or oil boilers.

The high annual performance factors (SPF) are reached by Heliotherm heat pumps, obtaining maximum subsidies and grants from the federal, municipal or utility companies. Subsidy awards vary from country and region to region.

Technical Specifications Heliotherm Heat Pumps

dsi Technology®: electronic working fluid regulation

By contrast, a conventional mechanical working fluid control, to a heat pump with the electronically controlled working fluid regulating device, patented dsi Technology® in the refrigeration cycle. This mechanism masters the difference in this cutting edge technology for higher efficiency. Additionally, more parameters can be taken into account and the expansion valve can respond faster to changes, adapting to the required operating conditions.

twin-x cooling optimization

Thanks to the patented twin-x cooling technology® exclusively by Heliotherm, unused energy can be extracted from the refrigeration circuit through a second special heat exchanger. The gained energy is delivered directly to the heating water. This process engineered by Heliotherm, contributes to an even better use of environmental energy.

Stepless modulation

Since 1994 Heliotherm is a pioneer in construction and development of heat pumps. Modulation is part of this company's Stepping Stones of research and development of modulation and is therefore the technology leader in this application. Heliotherm's stepless modulation technology has been proven for many years by its reliability and efficiency. The Heliotherm modulation technology opens up entirely new possibilities for the application of highly efficient heat pumps. As needed by the heating demand, the modulating heat pump can achieve the desired performance. In addition, the heat pump is protected by a soft start up conduct and its lifespan is prolonged.

Stepless modulation Heliotherm video

System Components

Fresh hot water system and buffer storage

The fresh hot water system is optimally adapted to Heliotherm heat pump products.

web control AT

Intelligent home automation can be centrally controlled with a variety of operating devices - on-site and on the road.